E-Cleaning a LeveLuk Jr IV

The LeveLuk Jr IV is cleaned with the E-Cleaner N: one pack of cleaning powder in a Cleaning Powder Unit, fitted where the water filter normally sits, and left to soak for three to five hours.

Enagic's manual calls this "Cleaning with the E-Cleaner N" rather than E-Cleaning. Most people search for it as E-Cleaning, so that is what this page is called, but the manual's own name is worth knowing when you are looking at the packaging.

The whole procedure is done with the machine switched off and unplugged. There is no cycle to start and nothing on the display. If you have read a guide describing a cleaning cycle you start from a screen, that was written for the K8, which cleans a different way entirely.

Everything below is from Enagic's own instruction manual, which covers the Jr IV and the SD501 together. Kanjuni is an independent platform and is not affiliated with Enagic International.

Source: Enagic LeveLuk SD501 / LeveLuk Jr IV Instruction Manual, pp. 31–33.

Watch Enagic Asia's video of this procedure

One manual covers the jr iv and the sd501

Enagic publishes a single instruction manual for the Jr IV (model TYH-251) and the SD501 (model TYH-401), and the cleaning procedure appears once, for both. There is no separate Jr IV method and no step that applies to one machine and not the other.

The two differ in flow rate and power consumption, and in one thing worth knowing here: the Jr IV has no voice guidance. The SD501 speaks; the Jr IV signals with an alarm and an LCD message instead. Nothing in the cleaning procedure depends on this, because the machine is off throughout, but it does change what a filter replacement notification looks like — see below.

When to clean

Enagic's manual gives the interval twice, in the same words both times: once every week to two weeks.

The manual also names the procedure as the remedy for several symptoms, which is usually what sends someone looking:

  • No water, or reduced output across all water types — after checking for a frozen unit, low water pressure, a clogged filter and a bent hose
  • Whitish material floating or settled in Kangen Water® — calcium processed by electrolysis
  • The pH dropping when producing Kangen Water® and Beauty Water, from calcium building up in the ionising cell

For that last one the manual offers a quicker thing to try first: press the Beauty button and run water for about one minute to clean the ionising cell. Worth doing before committing to a five-hour soak.

How hard your water is determines how fast calcium builds up, so the right interval is the one that suits your machine rather than the one in the manual.

Automatic cleaning is different

The Jr IV cleans itself, and it is not the same thing.

Automatic cleaning runs for 30 seconds. The manual lists three triggers: total operating time reaching 15 minutes, selecting another water type after producing Strong Acidic Water, or the unit sitting unused for 24 hours or more. The display shows CLEANS, and NOTICE CLEANING when a cycle is due.

It uses no cleaning powder and does not remove established calcium. Do not drink water produced during automatic cleaning — the manual says so directly, and lists cleaning cycle water among the waters not to be drunk.

What you need

  • The Cleaning Powder Unit (CPU-N)
  • One pack of cleaning powder. The manual is explicit that only the manufacturer's powder should be used, and that another powder could cause internal damage
  • A cup
  • The machine's own water filter holder

The cleaning powder contains citric acid. The manual notes this and warns against using water produced during cleaning to wash fruit and vegetables.

Replacement powder comes in boxes of 24. The CPU-N is a consumable and the manual says to replace it periodically, or immediately if the O-ring or cap is damaged.

The manual gives no weight or volume for a pack of powder — just one pack per treatment. Use a whole pack rather than measuring.

The procedure

Turn off the tap, switch the unit off and disconnect the plug before you start. The manual states this twice.

  1. Unscrew the cap of the CPU-N, pour the cleaning powder evenly into the bottom, and retighten the cap. Check the O-ring is seated.
  2. With the tap off, remove the filter cover from the main unit, rotate the holder and remove the water filter.
  3. Place the Cleaning Powder Unit on the main unit and secure it with the holder.
  4. Turn on the tap and let water flow through the flexible pipe for about ten seconds, roughly one litre, then turn the water off.
  5. Put the tip of the flexible pipe and the secondary water hose into the bottom of a cup, and run water until the cup is about half full. Turn off the tap and leave the pipe and hose in the cup for three to five hours. Make sure the cup cannot tip over.
  6. After three to five hours, remove the cup. Turn on the tap and let the water run for several minutes.
  7. Turn off the tap and refit the water filter you removed at step 2, checking both O-rings are seated. Turn the tap on again and run water for several minutes.
  8. Refit the filter cover and plug the machine back in. The cleaning is complete.

Two things the manual adds afterwards. Deposits may flow out for a while during normal use — if you find them in the water, discard it. And rinse the CPU-N thoroughly with tap water, dry it completely with a soft cloth, and store it dry.

The manual gives no total elapsed time. The soak is three to five hours; the flushes either side are "several minutes" each.

Cautions

Only use Enagic's cleaning powder. The manual states another manufacturer's powder could cause internal damage to the unit.

Never run water hotter than 40°C through the machine. The manual states this may damage it or cause malfunctions, and the unit has hot-water and overheat protection that will display a warning. The specification gives an available water temperature of 5°C to 35°C.

Do not use thinner, benzene, cleansers or chlorine-based detergents to clean the machine.

The unit contains no user-serviceable parts. Enagic's manual states all servicing must be done by an authorised service representative, and that modifying, overhauling or repairing it yourself risks fire or electric shock, with any consequences not compensated by the manufacturer.

Worth knowing: among the reasons the manual lists for a repair being charged for even under warranty are "trouble resulting from improper usage or failure to perform regular maintenance" and "trouble caused by sediment or lime scale deposits". Regular cleaning is not only about water quality.

Deep cleaning

Enagic recommends a deep clean once a year at a qualified service centre, and notes the interval may vary with the hardness of the source water.

The manual gives no procedure, because it is not one you perform. It goes to a service centre.

Filter replacement

Cleaning with the E-Cleaner N cleans the electrodes. It does not clean or replace the water filter, which is a separate consumable.

The manual gives no replacement interval. The specification says only that it "varies according to region and water quality". A figure of 6,000 litres appears in the specifications, but it is the capacity for removing chlorine, taste and odour — not a filter life, and the manual does not connect the two.

The machine tells you instead. When the filter needs replacing, the Jr IV sounds an alarm and displays REPLACE FILTER when the water supply is stopped. There is no voice guidance on the Jr IV, so the alarm and the display are the whole of the notification. The message does not appear while water is running, so stop the water to see it.

To replace it:

  1. Push the water filter cover hook on the left side of the unit and remove the cover.
  2. Turn the holder knob clockwise about 40 degrees to unlock it, then lift the filter out. Water may leak from the filter as it comes out.
  3. Check no old O-rings are left on the filter tray, insert the new filter firmly, and turn the holder knob anticlockwise about 40 degrees to lock it. Check both O-rings are on the filter and the holder is firmly in.
  4. Press the water filter reset switch. The display reads FILTER RESET. Refit the cover.

Run water through the machine for 15 minutes when using a new filter. The manual repeats this figure four times.

Expect cloudy water at first. The manual explains this is the activated charcoal settling. Keep running the water until it clears, and do not drink it while it is cloudy.

Use Enagic's own filter. The manual states other manufacturers' filters may cause malfunction. It names the part three different ways and gives no part number at all, so take the description to your dealer rather than hunting for a code.

If you are storing the machine over a cold period or leaving it unused for a long time, the manual says to remove the water filter and keep it separately, and not to touch the reset switch while it is out.

Sources

Every fact on this page comes from Enagic's instruction manual for the LeveLuk SD501 and LeveLuk Jr IV, document code 46-0117G. Cleaning with the E-Cleaner N is pages 31 to 33, automatic cleaning page 27, filter replacement pages 28 to 29, troubleshooting page 30, and the specifications page 35.

Where the manual is silent we have said so rather than filling the gap. It gives no filter replacement interval, no weight for a pack of cleaning powder, no plate count, and no total time for the cleaning procedure.

Questions

How long does cleaning a Jr IV take?

Three to five hours of soaking, plus a few minutes of flushing either side. The machine is off and unplugged throughout, so it is unattended time rather than time spent doing anything.

How often should I clean a Jr IV?

Enagic's manual says once every week to two weeks. Harder water builds calcium faster, so machines in hard-water areas reach the point sooner.

Is the Jr IV cleaned the same way as the SD501?

Yes. Enagic publishes one manual for both machines and the cleaning procedure appears once, for both. The Jr IV has no voice guidance, but nothing about the cleaning itself differs.

Is this the same as E-Cleaning a K8?

No. The K8 uses a cleaning tank and cartridge with a guided cycle on its touch display. The Jr IV uses a Cleaning Powder Unit and a soak with the power off. Neither procedure works on the other machine.

Why does my Jr IV not say anything?

It has no voice guidance — that is an SD501 feature. The Jr IV uses an alarm and the LCD instead, so watch the display rather than listening for it.

Can I use a different cleaning powder?

Enagic's manual states another manufacturer's powder could cause internal damage to the unit. The supplied powder contains citric acid.

How often should the filter be replaced?

The manual gives no interval — only that it varies by region and water quality. The machine tells you, displaying REPLACE FILTER when the water is stopped. The 6,000 litre figure in the specifications is a chlorine, taste and odour removal capacity rather than a filter life.

Why is my water cloudy after a filter change?

The manual attributes this to the activated charcoal settling. Keep running the water until it clears, and do not drink it while it is cloudy.

Do I need a deep clean as well?

Enagic recommends one a year at a qualified service centre, more often with hard water. It is not something you do yourself and the manual gives no procedure for it.