Replacing the cartridges in an Anespa DX

The Anespa DX takes two cartridges — a clean water cartridge and a ceramic cartridge — and replacing them is the only maintenance the manual describes.

Both come out together, in a particular order, and go back in the reverse order. It takes a few minutes and needs the spanner supplied with the unit.

Everything below is from Enagic's own operation manual for the Anespa DX. Kanjuni is an independent platform and is not affiliated with Enagic International.

Source: Enagic Anespa DX Operation Manual, ANSP-02, sections 1, 7 and 8.

Watch Enagic Canada's video of this procedure

There is no e cleaning on an anespa

If you have arrived from a guide about cleaning a Kangen Water® machine, stop looking for the equivalent here. There isn't one.

The Anespa DX is not an ioniser. It has no electrodes, no plates, no electrical supply and no controls beyond a mechanical selector. Water passes through two cartridges and that is the whole of it. There is no cleaning powder, no cleaning cycle, no soak, and nothing on any display, because there is no display.

The manual describes no way to clean the unit internally. Its only warning about internal condition is that leaving a cartridge in past its replacement time may cause clogging — and the remedy for that is a new cartridge rather than a cleaning process.

When to replace them

From the manual's specifications:

  • Clean water cartridge — about 1 year
  • Ceramic cartridge — about 3 years

Both are qualified the same way: "replacement timing varies depending on the water quality and quantity consumed."

The manual gives a second, different basis for the one-year figure, in a note about a fortnight earlier in the document, tying it to a daily volume. That figure is not reproduced here. It is not consistent with the specification table, it does not say which cartridge it refers to, and the number itself is implausible for a domestic shower unit. Where a manual contradicts itself we say so rather than picking one, and in this case neither reading is safe to publish as guidance.

Work to about a year for the clean water cartridge and about three years for the ceramic one, and replace sooner if flow drops.

Nothing tells you when it is due. There is no counter, no indicator and no alarm — the unit is not electrical. A water filter change seal is supplied in the box, presumably to write the date on, though the manual never explains what it is for or how to use it.

What you need

  • A new clean water cartridge, a new ceramic cartridge, or both
  • The spanner supplied with the unit, for the fixing nut

Enagic sells the pair together as a twin cartridge, and separately as a clean water cartridge for replacement and a ceramic cartridge for replacement.

There is no part number in the manual. Not for either cartridge. Take the description to your distributor or to Enagic rather than looking for a code.

The procedure

The manual's section is diagrams with numbered callouts rather than prose. The order below is its own.

Removing the old cartridges

  1. Remove the hot water outlet pipe.
  2. Remove the shower hose.
  3. Remove the tip-resistant ring.
  4. Remove the cartridge housing, using the supplied spanner on the fixing nut.
  5. Remove the old clean water cartridge.
  6. Remove the old ceramic cartridge.

Fitting the new ones

  1. Put in the new ceramic cartridge.
  2. Put in the new clean water cartridge.
  3. Install the cartridge housing and tighten the fixing nut.
  4. Fit the tip-resistant ring, and attach the suction cap to the plate.
  5. Insert the hot water outlet pipe.
  6. Install the shower hose.

Note the order reverses. The clean water cartridge comes out first and goes back in last; the ceramic cartridge comes out last and goes back in first.

Before using the unit with a new cartridge, run the water for two or three minutes.

Two things the manual does not say, worth knowing before you start. It gives no instruction to shut the water off first, which is an omission rather than permission — turn it off. And it gives no torque figure for the fixing nut, and mentions no seals or O-rings.

The temperature limit and what the manual says about it

Enagic's manual states two different maximum temperatures, in two places, and does not reconcile them.

The safety section says: "Though this product is designed for warm water, don't pass hot water (60℃ or more) through."

The specification table gives a maximum working temperature of 104°F, which is 40°C — and states the filtering performance and capacity at that same temperature.

Both are Enagic's own figures. We would work to the lower one. 40°C is where the manual says the unit is specified to perform, and a shower running above that is uncomfortable anyway. The 60°C figure is a prohibition rather than a working limit.

The manual also warns, plainly: "For the prevention of accident such as burn injury, before passing water through the unit, always adjust the water temperature and then use this product."

Other things the manual asks for

After two or three days unused, let the water flow for one to two minutes before using it.

In freezing weather, do not let the water in the unit freeze. The manual suggests letting a small quantity of water through when there is a risk of freeze-up.

Do not store the filtered water. The manual notes the water has had its chlorine removed and says to use it promptly rather than keeping it.

Cloudiness and bubbles on first use are normal. The manual states there is no harm from them.

Water quality and what voids the warranty

The manual is firm about what goes into the unit. Water not compatible with water supply regulations may limit the product's function, and Enagic states it accepts no responsibility in that case. The same applies if there is work being done on the water supply nearby, or if rusty water appears — the manual says never to use the unit in that situation.

The warranty terms list "trouble or damage due to use of water other than municipal drinking water" among the reasons a repair may be charged for, along with "trouble resulting from handling in a manner that is not specified in the operation manual" and replacement of consumable parts.

The manual also states the unit must not be modified, overhauled or repaired by the purchaser, and that any consequence of doing so is not compensated by the manufacturer.

A note on units

Enagic's manual for this product is printed entirely in US customary units — gallons, inches, pounds, psi and Fahrenheit. Where we have given a metric equivalent above it is our conversion rather than a figure from the manual, and it is marked as such.

The one exception is the 60°C prohibition, which the manual itself gives in Celsius.

Sources

Every fact on this page comes from Enagic's operation manual for the Anespa DX, type ANSP-02, document code 46-0105. Cartridge replacement is section 8, the intervals and specifications are section 7, and the safety and use instructions are section 1.

Where the manual is silent we have said so. It gives no part numbers, no troubleshooting table, no instruction to shut off the water before removing a cartridge, and no explanation of the water filter change seal supplied in the box. Where it contradicts itself — on temperature, and on the basis for the one-year cartridge interval — we have shown the disagreement rather than choosing.

Questions

How often do Anespa DX cartridges need replacing?

About a year for the clean water cartridge and about three years for the ceramic one, both qualified by water quality and how much water goes through. Replace sooner if the flow drops.

How do I know when they are due?

Nothing tells you. The Anespa DX has no counter, indicator or alarm, because it is not electrical. A water filter change seal comes in the box, presumably for writing the date on.

Do I replace both at once?

Not necessarily — they are on different schedules and are sold separately as well as together. But both have to come out to change either, so many people replace them together when the clean water cartridge is due for the third time.

Does the Anespa DX need E-Cleaning?

No. It has no electrodes and no cleaning cycle, and the manual describes no internal cleaning of any kind. Cartridge replacement is the only maintenance there is.

What part number do I ask for?

The manual gives none. Ask for a clean water cartridge, a ceramic cartridge, or a twin cartridge for both.

How hot can the water be?

The manual gives two figures and does not reconcile them: it prohibits water at 60°C or above, and specifies a maximum working temperature of 104°F, which is 40°C. We would work to 40°C.

What if I have not used it for a while?

Run the water for one to two minutes before using it if the unit has been unused for two or three days.

Can I clean a clogged cartridge instead of replacing it?

The manual gives no cleaning procedure for either cartridge. It warns that using the unit past the replacement time may cause clogging, and the remedy it describes is a new cartridge.